Who's Online
There currently are 5966 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is the correct service manual of SHARP RX-100H(BK) DAT.
;
The ervice manual for my 1982 Kenwood KR-1000 receiver is great! Full detail on all circuits with part number detail. I will definately be ordering more manuals for my other vintage equipment! Order was fulfilled quickly! Very efficient ordering process! Thnaks for your help! Great site!
;
Everything in the manual was excellent except for a couple of pictures of specific areas in the unit that were a little dark. Owners Manuals re-sent the pdf file & the problem was corrected. Excellent product! George
;
Thanks for offering this item at such a good price. Proved handy in identifying the part I was looking for my set.
Thanks again.
;
This is the original manufacturers service manual, with detailed info on the circit boards, explosion drawings of all parts in assembly order, and tuning instructions. The only thing missing is the information on the dimensions of the various drive belts. mail me if you need them. gcrossman_at_aol.com
CD Adjustment Method
� Perform the adjustments after the machine enters the test mode. � Place the CD mechanism horizontally level. � Equipment and tools required Measuring equipment: Oscilloscope (Use the probe of 10:1) Digital VOM (Use it in the DC Volt range.) Jitter meter (Kikusui 6235 or equivalent) Test disc: TCD-782 ATD-001
1. FOCUS BIAS Adjustment
1) 2) 3) Connect a digital VOM to the test point (FOCUS BIAS), (VREF). Play back the 2nd track of the TCD-782. Adjust SFR430 until the VOM indicates 0 +/-10 mV.
DIGITAL MULTIMETER V
+
FOCUS BIAS VREF
--
2. RF Waveform Check
OSCILLOSCOPE
1) 2) 3)
Connect an oscilloscope to test point (RF SM), (GND). Play back the 2nd track of the TCD-782. Check to see that the RF waveform has the maximum amplitude and the center of the wedge waveform has the clear blank.
RF SM VREF
1.8 Vp-p
OUTPUT
+
--
EYE PATTERN must be CLEAR and MAX.
0V
VOLT/DIV: 500mV TIME/DIV: 0.5µS
3. Jitter Check
1) While an oscilloscope is kept connected in the same test point as in the 2. RF Waveform Check, connect the output terminal of an oscilloscope to the input terminal of a jitter meter. Set the VOLT range selector of an oscilloscope to 500 mV range or lower. 3) 4) Play back the 2nd track of the TCD-782. Check to see that a jitter meter indicates 28.0 ns or less.
RF SM VREF OSCILLOSCOPE JITTER METER OUTPUT INPUT ns
2)
+
--
4. Tracking Balance Check
1) 2) 3) Connect an oscilloscope to test point (TE), (VREF). Play back the 2nd track of the TCD-782 and press the PAUSE button. Check to see that the traverse waveform on an oscilloscope is vertically symmetrical.
TE VREF OSCILLOSCOPE
VREF
OUTPUT
A B
+
--
A=B
VOLT/DIV: 500mV TIME/DIV: 1mS
5. Play-ability Check
1) Play back the 3rd, 8th and 13th track of ATD-001. Check to see that noise does not occur and sound skipping does not occur.
6. Laser Current Check
*Do not perform this measurement unless the laser is suspected to be defective. 1) Connect a digital VOM across the resistor R402 (10 ohms). 2) Play back the TCD-782 and check the DC voltage value on a digital VOM. 3) Calculate the laser current (Iop) by dividing the DC voltage across R402 by the resistor value (R402 = 10 ohms). Laser current (Iop) = DC voltage across R402 divided by the resistor value (10 ohms). Check to see that the laser current (Iop) is 80 mA or less.
DIGITAL MULTIMETER V
+
R402 R402
--