Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 272 guests online.
Categories
Information
Featured Product
Home >> AIWA >> XRM191 Service Manual
 
 0 item(s) in your cart 

AIWA XRM191
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of AIWA XRM191 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 MHC-1750 SONY Service Manual by Gerald Fudge;
More than pleased with my prurchase, very good product for the price.
 KR-V55R KENWOOD Service Manual by Joseph Souza;
This is a good quality scan of the service manual which includes an assembly diagram, block diagram, schematic, and parts list. Exactly what is needed to repair my KR-V55R receiver.
 SXKN1400 TECHNICS Service Manual by terry groves;
Excellent concise manual. All needed information was included. Typeface and diagrams were clear. Very fair price considering what others are charging. Many thanks
 PM711AV MARANTZ Service Manual by Dominic Azzopardi;
Response is a little slow- I had to wait 12 hours to receive download link but it says that it may take up to 24hrs. Manual is old and was not produced in PDF- scanned copy is exellent. Overall- value for money- I recommend
 SX-WSA1 TECHNICS Service Manual by Kurt Faasse;
Excellent quality and quickly delivered manuals at a fair price. Great care is taken in the reproduction process. Even photographs and highly detailed drawings are as clear as in the original. That cannot be said for some freelance manual copies I have obtained from the web. If you have exhausted your internet search of technical manuals, try Owner-Manuals.com. If they do not have it, I do not think it exists. Perhaps, if requested, they may be able to find it. Their resources are certainly greater than most. Shopping here certainly beats waiting for months or years for the manual you seek to appear in an internet auction or garage sale.

Text excerpt from page 31 (click to view)
ADJUSTMENT <TUNER / DECK>
< TUNER SECTION >
1. Clock Frequency Check Settings : • Test point : TP2 (CLK) Method : Set to AM 1710 kHz and check that the test point is 2160 kHz ± 45 Hz. 2. AM VT Check Settings : • Test point : TP1 (VT) Method : Set to AM 1710 kHz and check that the test point is less than 8.5 V. Then set to AM 530 kHz and check that the test point is more than 0.6 V. 3. AM Tracking Adjustment Settings : • Test point : TP8 (Rch), TP9 (Lch) • Adjustment location : L951(1/3) Method : Set to AM 1000 kHz and adjust L951(1/3) so that the test point becomes maximum. 4. AM IF Adjustment Settings : • Test point : TP8 (Rch), TP9 (Lch) • Adjustment location : L802 L802 ................................................... 450 kHz 5. FM VT Adjustment Settings : • Test point : TP1 (VT) • Adjustment location : L907 Method : Set to FM 108.0 MHz and adjust the L907 so that the test point is 7.00 V ± 0.05 V. 6. FM VT Check Settings : • Test point : TP1 (VT) Method : Set to FM 87.5 MHz check that the test point is more than 0.5 V. 7. FM Tracking Adjustment Settings : • Test point : TP8 (Rch), TP9 (Lch) • Adjustment location: L904 Method : Set to FM 98.0 MHz and adjust L904 so that the test point becomes maximum and distortion to minmum. 8. FM Tracking Check Settings : • Test point : TP8 (Rch), TP9 (Lch) Method : Set to FM 98.0 MHz and check that the test point is less than 9 dBµV. 9. DC Balance / Mono Distortion Adjustment Settings : • Test point : TP3, TP4 (DC Balance) TP8 (LCH), TP9 (RCH) (Mono Distortion) • Adjustment location : L801 • Input level : 60 dBµV Method : Set to FM 98.0 MHz and adjust L801 so that the voltage between TP3 and TP4 becomes 0 V ± 500 mV with minimum distortion. 10. Output Level Check <AM> Settings : • Test point : TP8 (Rch), TP9 (Lch) • Input level : 74 dBµV Method : Set to AM1000 kHz and check that the test point is 55 mV ± 3 dB. <FM> Settings : • Test point : TP8 (Rch), TP9 (Lch) • Input level : 60 dBµV Method : Set to FM 98.0MHz and check that the test point is 270 mV ± 3 dB. 11. FM Separation Check Settings : • Test point : TP8 (Rch), TP9 (Lch) • Input level : 60 dBµV Method : Set to FM 98.0 MHz and check that the separation more than 25 dB.

< DECK SECTION >
1. Tape Speed Check Settings : • Test tape : Method : TTA–100

• Test point : SP OUT Play back the test tape and check the test point is 3000 Hz ± 5 Hz (FWD) and FWD speed ± 45 Hz (REV).

2. Head Azimuth Adjustment Settings : • Test tape : TTA–330 • Test point : SP OUT • Adjustment location : Head azimuth adjustment screw Method : Play back (FWD) the 8 kHz signal of the test tape and adjust screw so that the output becomes maximum. Next, perform on REV PLAY mode. 3. PB Frequency Response Check Settings : • Test tape : TTA–320 • Test point : SP OUT Method : Play back the 315 Hz and 10 kHz signals of the test tape and check that the output ratio of the 10 kHz signal with respect to that of the 315 Hz signal is -3 dB ± 3 dB. 4. REC/PB Frequency Response Check Settings : • Test tape : TTA–602 • Test point : SP OUT • Input signal : 8 kHz/1 kHz (-20 VU / 0dB) Method : Apply a 1 kHz signal and REC mode. Record and play back the 1 kHz signals and check that the output is -2 dB ± 3 dB.

– 31 –

You might also want to buy

$4.99

XRM191 AIWA
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
>
Parse Time: 0.145 - Number of Queries: 108 - Query Time: 0.03