the big video recorder format s-vhs many features delicate in loading system of the cassette. Such machines are no longer manufactured, it would be too expensive.
;
THIS MANUAL IS VERY GOOD AND VERY CLEAR
PLEASE NOTE IT DOES NOT CONTAIN THE SETUP INFORMATION TO ALIGHN THE GEARS IN THE CD MECH IT DOES SHOW ALL THE PARTS AND THEIR LOCATIONS .
;
Complete service and operation manual. All schematics are there, all circuit boards AND add-on boards. Including exploded views ,component names and specifications. Also electrical and mechanical adjustment procedures are in this manual. This manual also covers the more advanced BR-S811E unit. Scan quality is fair and usable.
;
High quality scan of original Service Manual. Everything´s fine!
;
Good scan of the original service manual. All schematics and adjustment procedures are there. It helped me to fix a long lasting problem with the tracking circuitry. The manual also includes the supplementals 1,2 and 3. Included are; electrical schematic's , pcb layout's, mechanical drawing's and exploded views, disassembly manual and maintenance procedures. 236 pages.
3.JITTER CHECK 1) While oscilloscope is kept connected in the same test point as in step2. RF WAVEFORM CHECK, connect the output terminal of an oscilloscope to the input terminal of the jitter meter. 2) 3) 4) Set the VOLT range selector of oscilloscope to 500mV range or below. Play back 2nd track of TCD-782.
RF SW OUTPUT INPUT ns OSCILLOSCOPE JITTER METER
Check that jitter meter indicates 28.0ns or less.
Vref
4. PLAY ABILITY CHECK 1) Play back the 3rd , 8th and 13th track of ATD-001. Check that the noise does not occur sound skipping does not occur.
5.LASER CURRENT CHECK *Do not perform this measurement unless the laser is suspected to be defective. 1) 2) 3) Connect digital multi-meter across the resistor R402(10Ω). Play back the TCD-782 and check the DC voltage value on the digital multi-meter. Calculate the laser current (Iop) by dividing the DC voltage across R402 by the resistor value (R402= 10Ω). Check that the laser current (Iop) is 60mA or less.
R402 R402 DIGITAL MULTIMETER V