Everything was great, the manual, the response time, the simplicity of the order, and the
Price. The only thing that I could possible say on a negative note would be that the manual I ordered was more for a service tech. There were a lot of schematic diagrams that didn't help me solve the problem. However I would order again and recommend the web sight to others.
very complete. acceptable resolution. details are a little unclear. is a manual note 8.
Text excerpt from page 24 (click to view)
4. Confirmation of the RF level
Test point: RF and VC (Vref) Test disc: TCD-782 Confirm that the RF waveform appears as shown below.
At 0.8 Vp-p or greater
VOLT/DIV: 200mV TIME/DIV: 0.5us
5. Confirmation of tracking balance
Test point: TE and VC (Vref) Test disc: TCD-782 Press the DSL button while the test disc is playing and confirm that the traverse waveform is as is shown below.
VC
VOLT/DIV: 200mv TIME/DIV: 2ms
6. Confirmation of each servo
It is possible to confirm the adjustment value of each servo by repeatedly pressing the MODE button while the test disc is playing. The switchover sequence is as stated below. Confirmation mode OFF -> Focus bias (FB) -> Tracking balance (TB) -> Tracking gain (TG) -> Tracking error offset (TEO) -> Focus gain (FG) -> Focus error offset (FEO) -> Confirmation mode OFF Example: Tracking error offset (TEO) Adjustment value-> 03