Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
;
muy buen manual completo de buena calidad de impresion preciso y detallado , muy útil para la reparación.
;
The service manual is a good quality scan of the Panasonic NV-850, which is electrically identical to the Philips VR 6920, but mecanically just nearly.
ELECTRICAL ADJUSTMENT-7/8
2. Servo Adjustment (RF PLL Adjustment)
* * This adjustment can be performed even when the TOP cabinet, operation board or TFT block is removed. To avoid counting track jumps as errors, track jumps are not performed in the test mode and recorded spiral pits are read, unlike during normal DVD playback. Therefore, during service mode startup, only the Aiwa logo appears; the pictures and sound recorded on the disc are not output. During test mode startup, the OPEN/CLOSE detection switch is disabled. During test mode startup, keys other than the POWER key are disabled. The test mode automatically ends after 6 minutes (The disc rotation stops.) To continue the test mode, turn on the power again.
* * *
<XD-DW5 MODEL>
No. 1 2 3 4 5 6 7 8 9 10 Contents Short pin-4 and pin-6 (ground) of CN400 (not mounted). (Preparation for test mode startup) Connect CH1 of the oscilloscope to TP400 (IC400 pin-5) and connect CH2 to TP315 (IC450 pin-60). Insert the test disc (MDVD-191). Turn on the power. (The test mode starts.) Confirm that the pickup reads the outermost circumference of the disc. Rotate VR300 right while checking the waveform of TP315 becomes 4.5±1.0V. Check that the waveform of TP315 is fixed HIGH and the voltage of TP400 is less than 400mV. Turn off the power and turn on again. Confirm that the pickup moves to the innermost circumference. Check that the waveform of TP315 is fixed HIGH and the voltage of TP400 is less than 400mV.
<XD-DW7 MODEL>
No. 1 2 3 4 5 6 Contents Short pin-4 and pin-6 (ground) of CN400 (not mounted). (Preparation for test mode startup) Connect CH1 of the oscilloscope to TP400 (IC400 pin-5) and connect CH2 to TP315 (IC450 pin-60). Insert the test disc (MDVD-191A). Turn on the power. (The test mode starts.) Confirm that the pickup reads the innermost circumference of the disc. Gently rotate VR300 left while checking the waveform of TP400.(The waveform moves rapidly) Then rorate VR300 right gently so that the voltage of TP400 is minimized (less than 400mV). 7 8 9 10 Rotate VR300 left so that the voltage of TP400 is 50mV more than minimum value. Turn off the power and turn on again. Confirm that the pickup moves to the outermost circumference. Check that the waveform of TP315 is fixed HIGH and the voltage of TP400 is less than 400mV.
-76-
$4.99 XDDW7 AIWA Owner's Manual Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
|
|
|
> |
|