Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Helpd me mont a new carradio when prewius mont was a mess.
;
Very good service and quick service, very good quality of service manual!
;
Great tape deck manual!
I'm very positively surprised, because it is a very long manual, lot of pages, drawings, diagrams, description of how to make the alignment and adjustment procedures.
It is as good as the old "Naka" manuals from the 1970's - if somebody have seen them, they know what I mean by that.
I recommend to buy this very much !
;
I am a vintage hifi collector. No way to fix that device without the appropriate service manual...thanks to your site I got it and every thing is easier now. I got the manual right after ordering: fast cheap accurate ... thank you
;
Wonderful job clear. Qick fantastic. These people are really good. If even a problem arise they are wonderful assisting you. These scheme is so net despite this is a very old TV. Thank you for everything!!!!!!!!
ELECTRICAL ADJUSTMENT -2/7
<TUNER Adjustment> 1. VT Check (MW) Requirements � Measuring instrument: Digital multimeter Test points: VT, GND 1) Connect the digital multimeter between VT and GND. 2) Set the function to MW, and tune the receiving frequency of the unit at 1,602 kHz. 3) Check that the digital multimeter ranges under 9 V. 4) Tune the receiving frequency of the unit at 531 kHz. 5) Check that the digital multimeter ranges above 0.5 V. 2. VT Adjustment (LW) Requirements: Same as above. � Adjustment point: L942 1) Connect the digital multimeter between VT and GND. 2) Set the function to FM, and tune the receiving frequency of the unit at 144.0 kHz. 3) Adjust L942 so that the digital multimeter ranges at 1.3 ± 0.05 V. 3. VT Adjustment and Check (FM) Requirements: Same as the above. ï Adjustment point: L907 1) Connect the digital multimeter between VT and GND. 2) Set the function to FM, and tune the receiving frequency of the unit at 108.0 MHz. 3) Adjust L907 so that the digital multimeter ranges at 7.0 ± 0.1 V. 4) Tune the receiving frequency of the unit at 87.5 MHz. 5) Check that the digital multimeter ranges under 0.5 V. 4. CLOCK Check (MW) Requirements � Measuring instrument: Frequency counter Test point: CLOCK (IC801 24PIN), GND 1) Connect the frequency counter between CLOCK and GND. 2) Set the function to MW, and tune the receiving frequency of the unit at 1,710 kHz. 3) Check that the frequency counter ranges at 2,160 kHz ± 45 Hz.
-35-
|
|
|
> |
|