Who's Online
There currently are 5972 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I had been looking everywhere for a proper service manual for this VCR. Everywhere else that has this available for download has a very light version. This is the full service manual with all aspects that would interest anyone looking for the service manual for the AIWA HV-MX100 Worldwide VHS VCR. Great quality (as always). A winner hands down. Best Quality.
;
Top quality manual. Covers all aspects you'd expect in a top quality service manual for this Panasonic VHS VCR. The manual resolution is high. Another top quality manual from the only site worth downloading manuals from! If you're looking for a manual for the PV-9662 VHS VCR, this is the one you'll want to get!
;
complete part-lists and pcb layout, schematic diagram is good enlargable,
;
Excellent, fast delivery, excellent product. Good luck!
;
This manual is for the usa model only. But it is clear
, accurate and comprehensive, including board layouts and schematics.
I found it extremely useful for my mitsubishi dp-86da, but the same diagram would also work for the realistic lab5000 and hi fi 80. Thanks.
ADJUSTMENT <DECK> (FX-NH2000)
< DECK SECTION >
1. Tape Normal Speed Adjustment Settings : � Test tape : TTA�100 (Tape center) � Test point : TP1 (Rch), TP2 (Lch) � Adjustment location : SFR1 Method : Play back the test tape and adjust SFR1 so that the test point becomes 3000Hz ± 5Hz(FWD) Then check REV speed is 3000Hz ± 45Hz. 2. High Speed Check Settings : � Test tape : TTA�100 (Tape center) � Test point : TP1 (Rch), TP2 (Lch) Method : After normal speed adjustment, play back (High speed) the test tape. Then check tape speed is 6000Hz ±400Hz (FWD). 3. Head Azimuth Adjustment Settings : � Test tape : TTA�300 � Test point : TP1(Rch), TP2 (Lch) � Adjustment location : Head azimuth adjustment screw Method : Play back the 10kHz signal of the test tape and adjust screw so that the output becomes maximum.Next, perform on each FWD PLAY and REV PLAY mode. 4 PB Sensitivity Adjustment (DECK1, DECK2) Settings : � Test tape : TTA�200 � Test point : TP1 (Rch), TP2 (Lch) � Adjustment location : SFR301 (DECK1, Lch) SFR302 (DECK1, Rch) SFR303 (DECK2, Lch) SFR304 (DECK2, Rch) Method : Play back the test tape and adjust SFRs so that the output level of the test point becomes 245mV (DECK2), 260mV (DECK1). 6. REC/PB Sensitivity Adjustment (DECK2) Settings : � Test tape : TTA�602 (NORMAL) � Test point : TP1 (Rch), TP2 (Lch) � Input signal : 1kHz (LINE IN) � Adjustment location : SFR305 (Lch) SFR306 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 0dB (17mV). Record and play back the 1kHz signals and adjust SFRs so that the output is 0dB ± 0.5dB. 7. REC/PB Frequency Response Adjustment (DECK2) Settings : � Test tape : TTA�602 (NORMAL) � Test point : TP2 (Lch), TP1 (Rch) � Input signal : 1kHz / 10kHz (LINE IN) � Adjustment location : SFR351 (Lch) SFR352 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 0dB (17mV). Record and play back the 1kHz and 10kHz signals and adjust SFRs so that the output level of the 10kHz signals becomes 0dB ± 0.5dB with respect to that of the 1kHz signal. 8. REC/PB Frequency Response Check (DECK2) Settings : � Test tape : TTA�615 (CrO2) � Test point : TP2 (Lch), TP1 (Rch) � Input signal : 1kHz Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 0dB (17mV). Record and play back the 1kHz signal and check that the output is 0dB ± 2.0dB. 9. REC/PB Sensitivity Check (DECK2) Settings : � Test tape : TTA�615 (CrO2) � Test point : TP2 (Lch), TP1 (Rch) � Input signal : 1kHz (LINE OUT) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 170mV. Record and play back the 1kHz signal and check that the output is 0dB ± 2.0dB.
5. PB Frequency Response Check (DECK1, DECK2) Settings : � Test tape : TTA�300 � Test point : TP1 (Rch), TP2 (Lch) Method : Play back the 315Hz and 10kHz signals of the test tape and check that the output ratio of the 10kHz signal with respect to that of the 315Hz signal is 0dB . Next, check that the Lch and Rch difference level of 10kHz signal is less than 2dB.